Motor Protection Relay by Solcon USA
Full featured motor protection relay
The MPS 3000 provides comprehensive motor protection.
Thermal capacity and overload calculations with bias input from current imbalance
(positive/negative sequence) and temperature sensors ensure accurate modeling of your motor's condition.
Advanced Protection
- Max. Start Time (48)
- Too Many Starts Level 1 (66)
- Undercurrent Level 1 (37)
- Undercurrent Level 2 (37)
- Load Increase - Alarm (51L)
- Over Current Level 1 - Jam (51R)
- Over Current Level 2 - Short (50)
- Thermal Capacity Level 1 (49/51)
- Thermal Capacity Level 1 (49/51)
- Current Imbalance Level 1 (46)
- Current Imbalance Level 2 (46) (Positive / Negative Sequence)
- Under-voltage (27)
- Over-voltage Level 1 (59)
- Over-voltage Level 2 (59)
- Phase loss (47)
- Phase sequence (47)
- Ground Fault Level during starting (50G)
- Ground Fault Level 1 (50G)
- Ground Fault Level 2 (50N)
- Communication failure (3)
- Internal failure (3)
- External Fault 1 - interlock (86 or 94)
- External Fault 2 - interlock (86 or 94)
- External Fault 3 - interlock (86 or 94)
- High Temp. Level 1, sensors 1-10 (49R)
- High Temp. Level 2, sensors 1-10 (49R)
- Under Power Level 1 (32L)
- Under Power Level 2 (32R)
- Low Power Factor (55)
Level 1 & 2 can be used for Alarm & Trip or both for trip with different time delays
Protection functions
Each protection can be designated as:
- Alarm Fail-safe
- Trip (or Trip Fail-safe)
- Auto Reset
- Panel Reset
- Remote Reset
Inputs
- Control supply 120-230V, AC/DC Optional 19-60VDC
- 3 phase voltage, directly up to 690V, Above 690V through PT
- Three phase currents C.T. Sec. 1 or 5A
- Ground current C.T. Sec. 1 or 5A
- 10 temperature sensors, with two types:
- 10 RTD-Pt100 (or CU)
- 6 RTD-Pt100 (or CU) and 4 Thermistors (Programmable as NTC or PTC)
- 4 Programmable discrete inputs
- 4 Programmable Analog Inputs 0/4-20mA. (0-1mA by special order).
Outputs
- 4 Programmable Relays 8A, 250VAC.
- Four Programmable Analog Outputs, 0/4-20mA (0-1mA by special order)
Emergency Start (key operated function)
Display - LCD
Large LCD, 150mm x 30mm (6" x 1")
Measured values (True R.M.S. at a sampling rate of 0.5 msec.).
- Three phase voltage phase to phase
- Three phase voltage phase to neutral
- Current each phase
- Ground current
- Temperature / Resistance each sensor
- Energy with programmable pulse output
- Power, Reactive power, Power factor
- Minimum & Maximum RMS Average value (three phases) of Voltage, Current and Frequency
Calculated data
- Motor current in % of FLC
- Imbalanced current
- Thermal capacity
- Time to trip
- Time to start (after fault)
Statistical data
- Total run time
- Total number of starts
- Total number of trips
- Last start time period
- Last start current peak
- Energy
Fault data
- Last trip
- Last alarm
- Trip current each phase
- Trip earth fault current
- Trip voltage (each phase)
- List of last 10 trips with time stamp (Date, Hour, Minutes).
Display - LEDs
- On
- Stopped
- Starting
- Running
- Relay A
- Relay B
- Alarm
- Trip
- Internal Failure
Communication
RS 485, half duplex, MODBUS Protocol, baud rate 1200-19200 bits/sec. enables parameter change, supervision and remote resetting.
20 user-selectable parameters grouping of Actual Data.
Other protocols (plug-in board) - consult factory.
Real Time Clock
Time stamp for each fault - Date, Hour and Minute.
Fault Simulation
Simulation of voltage, currents and temperature faults enables relay testing.
This simulation Program allows testing and self learning of the MPS 3000.
Dimensions (mm) & Weight (kg)
Horizontal: W-310, H-135, D-160, 3.3Kg
Vertical: W-135, H-310, D-160, 3.3Kg
Available types
MPS-3000/P - Protection only system
MPR-3000/C - Protection & Control System
MPS-3000/C
Similar to the MPS-3000/P except with 16 discrete inputs to enable full control (start, stop, rotation direction change, etc.)
The MPS-3000 also incorporates two additional protection functions:
- Control Circuit Open (74)
- Welded Contactor (74)